Billing Codes

BB403

Aesculap-Miethke GAV Shunt System

Current benefit
$1697.00
ARTG numbers
Last updated
July 2023
Category
04 - Neurosurgical
04.03 - HYDROCEPHALUS DEVICES
Status
Unchanged
Size / specification

Valve: do=4.2 mm, Connector: do=1.9 mm Catheter: di=1.2 mm, do=2.5 mm, 5cmH2O-30cmH2O

Description

Single valve, (anti-siphon) gravitational shunt, titanium construction (MRI safe to 3 tesla), with incorporated reservoir, distal catheter and ventricular catheter.

Device identification (UDI)
Valve, hydrocephalic · Class IIb
04041906101008 ↗ 04041906101107 ↗ 04041906113001 ↗ 04041906113209 ↗ 04041906113308 ↗ 04041906114534 ↗ 04041906114558 ↗ 04041906114565 ↗ 04041906114800 ↗ 04041906115005 ↗ 04041906115104 ↗ 04041906125004 ↗ 04041906125202 ↗ 04041906133078 ↗ 04041906133085 ↗ 04041906133092 ↗ 04041906136529 ↗ 04041906136802 ↗ 04041906137113 ↗ 04041906137120 ↗ 04041906137571 ↗ 04041906137786 ↗ 04041906139988 ↗ 04041906139995 ↗ 04041906140007 ↗ 04041906140014 ↗ 04041906140021 ↗ 04041906140038 ↗ 04041906140403 ↗ 04041906140410 ↗ 04041906140427 ↗ 04041906140434 ↗ 04041906140441 ↗ 04041906140458 ↗ 04041906500009 ↗ 04041906500016 ↗ 04041906500023 ↗ 04041906500030 ↗ 04041906500047 ↗ 04041906500054 ↗ 04041906501624 ↗ 04041906501631 ↗ 04041906501648 ↗ 04041906501655 ↗ 04041906501662 ↗ 04041906501679 ↗ 04041906502317 ↗ 04041906502348 ↗ 04041906502355 ↗ 04041906502447 ↗ 04041906502454 ↗ 04041906502461 ↗ 04041906502478 ↗ 04041906502485 ↗ 04041906502492 ↗ 04041906503086 ↗ 04041906503093 ↗ 04041906503109 ↗ 04041906503116 ↗ 04041906503123 ↗ 04041906503130 ↗ 04041906503260 ↗ 04041906503277 ↗ 04041906503284 ↗ 04041906503291 ↗ 04041906503307 ↗ 04041906503314 ↗ 04041906503772 ↗ 04041906503789 ↗ 04041906503796 ↗ 04041906503802 ↗ 04041906503819 ↗ 04041906503826 ↗ 04041906504014 ↗ 04041906504021 ↗ 04041906504038 ↗ 04041906504045 ↗ 04041906504052 ↗ 04041906504069 ↗ 04041906504397 ↗ 04041906504403 ↗ 04041906504410 ↗ 04041906504427 ↗ 04041906504793 ↗

84 UDI-DI records matched via ARTG 181718, 375142 — sourced from the TGA Australian UDI Database (AusUDID). Click a number to look it up on AusUDID's own search.

TGA safety record
Not yet checked against TGA's safety database
Check on TGA ↗

Count and link only, sourced from the TGA's Database of Recalls, Product Alerts and Product Corrections. "Market actions" includes recalls, product alerts and product corrections — full detail stays on the TGA's own site.

Benefit history

No recorded changes yet — history accumulates with each release.

Data sourced from Australian Government publications · Not an official government service